Grade Separation at Adlieh Junction consisting of a main two-cell cut and cover underpass of total length 527m (covered length 182m) joining a one-cell cut and cover underpass of total length 322m (covered length 167m). The clear width of each cell of the two-cell underpass is 8.35m allowing for a 7.5m roadway. The clear roadway width of the one-cell tunnel is 5.5m.
Services Undertaken included Review of Feasibility Study, Preparation of Final Detailed Design and Production of Packages of Plans, Environmental Monitoring Studies, Specifications and Construction Cost Estimates.
Work included: